CITECT SCADA POP UP 8+ TAG (CICODE)

FUNCTION XGIPAM_POPUP(STRING EQUIPMENT) AssVarTags(-2, 0,EQUIPMENT+"\MMXU3\PPV\phsAB", EQUIPMENT+"\MMXU3\PPV\phsBC", EQUIPMENT+"\MMXU3\PPV\phsCA", EQUIPMENT+"\MMXU1\A\phsA", EQUIPMENT+"\MMXU1\A\phsB", EQUIPMENT+"\MMXU1\A\phsC", EQUIPMENT+"\MMXU1\Hz", EQUIPMENT+"\MMXU1\TotPF"); AssVarTags(-2, 8,EQUIPMENT+"\MMXU1\TotW", EQUIPMENT+"\MMXU1\TotVAr"); AssWin("!POP_XGIPAM",20,20,1); WinTitle(EQUIPMENT+" ...
READMORE
 

Computer Setup Editor CITECT SCADA

Alarm Format, untuk status alarm / event title bar yang di atas Protocol MODNET (Modbus) Settingan untuk Power Wizard 2.1 Settingan untuk Monitor display HD1080, fungsinya agar semua Page di SCADA memiliki display yg sama yaitu HD1080 dan ini adalah syarat dari monitor display settingan yang ada di computer...
READMORE
 

Program PLC 1 Tombol untuk START dan STOP

%M17 adalah address untuk START atau STOP dan coil yang di aktifkan adalah %M16. menggunakan Timer selama 2 Second untuk fungsi PB Start dan Stop , seperti pada gambar. ...
READMORE
 

Timer Countdown Programming PLC M221 Schneider

Timer Countdown Programming PLC Modicon M221 Schneider Electric ...
READMORE
 

Adaptable Tank Level Monitoring CITECT SCADA

Object Properties - Fill (Level)  The fill level of an object/group can be changed during runtime, increasing or decreasing dynamically whenever the value of a particular expression changes. As the value of the expression increases and decreases, the fill level will increase and decrease accordingly (as a percentage of the full capacity...
READMORE
 

Link Page CITECT SCADA

Displays a graphics page in the active window. The page needs to be in one of the operator's current areas. You can specify either the Page Name or the Page Number of the graphics page. You can also specify if the page operates within the context of a particular cluster in a multiple cluster project. When the page launches during runtime,...
READMORE
 

Button Confirm CITECT SCADA

Message Displays a message box on the screen and waits for the user to select the OK or Cancel button. This function is a blocking function. It will block the calling Cicode task until the operation is complete. This function will be blocked if called from a non-client process, as well as from kernel window of a client process if...
READMORE
 

Input Values CITECT SCADA

%Equipment%_TIM_LUB_ON ========================== %Equipment% adalah untuk addresse Ginie _TIM_LUB_ON adalah alamat Variable Tag %Equipment%_TIM_LUB_ON = FormNumPad("Enter The Value",%Equipment%_TIM_LUB_ON,0) %Equipment%_TIM_LUB_ON = Arg1 ============================= Keyboard Command Hasil dan Tampilan ...
READMORE
 

Easy Harmony HMI GXU Schneider Electric

INTRODUCTION THE EASY HARMONY GXU In this Module we will: Features Benefits Aplications Range of Panels Hardware & Accessories Overview Configurations Functions FEATURES TFT color screens, USB connection, Ethernet port The panels reach a maximum thickness of 38 mm Free communication wiring slot Configuration with Vijeo Designer...
READMORE
 

READ VAR & READ Power Meter (PM) PLC Schneider M221

PLC A  PLC B HMI ...